gsw_t_from_CT

in-situ temperature from Conservative Temperature

Contents

USAGE:

t = gsw_t_from_CT(SA,CT,p)

DESCRIPTION:

Calculates in-situ temperature from Conservative Temperature of seawater.
TEOS-10
Click for a more detailed description of calculating
in-situ temperature from Conservative Temperature.

INPUT:

SA  =  Absolute Salinity                                        [ g/kg ]
CT  =  Conservative Temperature                                [ deg C ]
p   =  sea pressure                                             [ dbar ]
       ( i.e. absolute pressure - 10.1325 dbar )
SA & CT need to have the same dimensions.
p may have dimensions 1x1 or Mx1 or 1xN or MxN, where SA and CT are MxN.

OUTPUT:

t   =  in-situ temperature (ITS-90)                            [ deg C ]

EXAMPLE:

SA = [34.7118; 34.8915; 35.0256; 34.8472; 34.7366; 34.7324;]
CT = [28.8099; 28.4392; 22.7862; 10.2262;  6.8272;  4.3236;]
p =  [     10;      50;     125;     250;     600;    1000;]
t = gsw_t_from_CT(SA,CT,p)
t =
  28.785580227725703
  28.432872246163946
  22.810323087627076
  10.260010752788906
   6.886286301029376
   4.403624452383043

AUTHOR:

Trevor McDougall & Paul Barker       [ help@teos-10.org ]

VERSION NUMBER:

3.05 (16th February, 2015)

REFERENCES:

IOC, SCOR and IAPSO, 2010: The international thermodynamic equation of
 seawater - 2010: Calculation and use of thermodynamic properties.
 Intergovernmental Oceanographic Commission, Manuals and Guides No. 56,
 UNESCO (English), 196 pp.  Available from the TEOS-10 web site.
  See sections 3.1 and 3.3 of this TEOS-10 Manual.
The software is available from http://www.TEOS-10.org