gsw_pot_enthalpy_from_pt
potential enthalpy from potential temperature
Contents
USAGE:
pot_enthalpy = gsw_pot_enthalpy_from_pt(SA,pt)
DESCRIPTION:
Calculates the potential enthalpy of seawater from potential
temperature (whose reference sea pressure is zero dbar).
INPUT:
SA = Absolute Salinity [ g/kg ]
pt = potential temperature (ITS-90) [ deg C ]
SA & pt need to have the same dimensions.
OUTPUT:
pot_enthalpy = potential enthalpy [ J/kg ]
EXAMPLE:
SA = [34.7118; 34.8915; 35.0256; 34.8472; 34.7366; 34.7324;]
pt = [28.7832; 28.4209; 22.7850; 10.2305; 6.8292; 4.3245;]
pot_enthalpy = gsw_pot_enthalpy_from_pt(SA,pt)
pot_enthalpy =
1.0e+005 *
1.150054085345822
1.135253087024591
0.909596876993543
0.408215028045380
0.272532147222681
0.172591013118296
AUTHOR:
David Jackett, Trevor McDougall and Paul Barker [ help@teos-10.org ]
VERSION NUMBER:
3.05 (16th February, 2015)
REFERENCES:
IOC, SCOR and IAPSO, 2010: The international thermodynamic equation of
seawater - 2010: Calculation and use of thermodynamic properties.
Intergovernmental Oceanographic Commission, Manuals and Guides No. 56,
UNESCO (English), 196 pp. Available from the TEOS-10 web site.
See section 3.2 of this TEOS-10 Manual.
The software is available from http://www.TEOS-10.org